summaryrefslogtreecommitdiff
path: root/docs/manpages/rpcclient.1
blob: 6ff5576349e92e1ba4138998eb880d5a7bd379c6 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
.\" This manpage has been automatically generated by docbook2man 
.\" from a DocBook document.  This tool can be found at:
.\" <http://shell.ipoline.com/~elmert/comp/docbook2X/> 
.\" Please send any bug reports, improvements, comments, patches, 
.\" etc. to Steve Cheng <steve@ggi-project.org>.
.TH "RPCCLIENT" "1" "26 November 2002" "" ""
.SH NAME
rpcclient \- tool for executing client side  MS-RPC functions
.SH SYNOPSIS

\fBrpcclient\fR [ \fB-A authfile\fR ] [ \fB-c <command string>\fR ] [ \fB-d debuglevel\fR ] [ \fB-h\fR ] [ \fB-l logfile\fR ] [ \fB-N\fR ] [ \fB-s <smb config file>\fR ] [ \fB-U username[%password]\fR ] [ \fB-W workgroup\fR ] [ \fB-N\fR ] [ \fB-I destinationIP\fR ] \fBserver\fR

.SH "DESCRIPTION"
.PP
This tool is part of the  Samba suite.
.PP
\fBrpcclient\fR is a utility initially developed
to test MS-RPC functionality in Samba itself.  It has undergone 
several stages of development and stability.  Many system administrators
have now written scripts around it to manage Windows NT clients from 
their UNIX workstation. 
.SH "OPTIONS"
.TP
\fBserver\fR
NetBIOS name of Server to which to connect. 
The server can be  any SMB/CIFS server.  The name is 
resolved using the   \fIname resolve order\fR line from 
\fIsmb.conf(5)\fR.
.TP
\fB-A|--authfile=filename\fR
This option allows 
you to specify a file from which to read the username and 
password used in the connection.  The format of the file is 


.nf
		username = <value> 
		password = <value>
		domain   = <value>
		
.fi

Make certain that the permissions on the file restrict 
access from unwanted users. 
.TP
\fB-c|--command='command string'\fR
execute semicolon separated commands (listed 
below)) 
.TP
\fB-I IP-address\fR
\fIIP address\fR is the address of the server to connect to. 
It should be specified in standard "a.b.c.d" notation. 

Normally the client would attempt to locate a named 
SMB/CIFS server by looking it up via the NetBIOS name resolution 
mechanism described above in the \fIname resolve order\fR 
parameter above. Using this parameter will force the client
to assume that the server is on the machine with the specified IP 
address and the NetBIOS name component of the resource being 
connected to will be ignored. 

There is no default for this parameter. If not supplied, 
it will be determined automatically by the client as described 
above. 
.TP
\fB-l|--logfile=logbasename\fR
File name for log/debug files. The extension 
\&'.client' will be appended. The log file is
never removed by the client.
.TP
\fB-N|--nopass\fR
instruct \fBrpcclient\fR not to ask 
for a password.   By default, \fBrpcclient\fR will
prompt for a password.  See also the \fI-U\fR
option.
.TP
\fB-s|--conf=smb.conf\fR
Specifies the location of the all-important 
\fIsmb.conf\fR file. 
.TP
\fB-U|--user=username[%password]\fR
Sets the SMB username or username and password. 

If %password is not specified, the user will be prompted. The 
client will first check the \fBUSER\fR environment variable, then the 
\fBLOGNAME\fR variable and if either exists, the 
string is uppercased. If these environmental variables are not 
found, the username GUEST is used. 

A third option is to use a credentials file which 
contains the plaintext of the username and password.  This 
option is mainly provided for scripts where the admin does not 
wish to pass the credentials on the command line or via environment 
variables. If this method is used, make certain that the permissions 
on the file restrict access from unwanted users.  See the 
\fI-A\fR for more details. 

Be cautious about including passwords in scripts. Also, on 
many systems the command line of a running process may be seen 
via the \fBps\fR command.  To be safe always allow 
\fBrpcclient\fR to prompt for a password and type 
it in directly. 
.TP
\fB-W|--workgroup=domain\fR
Set the SMB domain of the username.   This 
overrides the default domain which is the domain defined in 
smb.conf.  If the domain specified is the same as the server's NetBIOS name, 
it causes the client to log on using the  server's local SAM (as 
opposed to the Domain SAM). 
.SH "COMMANDS"
.PP
\fBLSARPC\fR
.TP 0.2i
\(bu
\fBlsaquery\fR
.TP 0.2i
\(bu
\fBlookupsids\fR - Resolve a list 
of SIDs to usernames.
.TP 0.2i
\(bu
\fBlookupnames\fR - Resolve a list 
of usernames to SIDs.
.TP 0.2i
\(bu
\fBenumtrusts\fR
.PP
.PP
\fBSAMR\fR
.TP 0.2i
\(bu
\fBqueryuser\fR
.TP 0.2i
\(bu
\fBquerygroup\fR
.TP 0.2i
\(bu
\fBqueryusergroups\fR
.TP 0.2i
\(bu
\fBquerygroupmem\fR
.TP 0.2i
\(bu
\fBqueryaliasmem\fR
.TP 0.2i
\(bu
\fBquerydispinfo\fR
.TP 0.2i
\(bu
\fBquerydominfo\fR
.TP 0.2i
\(bu
\fBenumdomgroups\fR
.PP
.PP
\fBSPOOLSS\fR
.TP 0.2i
\(bu
\fBadddriver <arch> <config>\fR 
- Execute an AddPrinterDriver() RPC to install the printer driver 
information on the server.  Note that the driver files should 
already exist in the directory returned by  
\fBgetdriverdir\fR.  Possible values for 
\fIarch\fR are the same as those for 
the \fBgetdriverdir\fR command.
The \fIconfig\fR parameter is defined as 
follows: 


.nf
		Long Printer Name:\\
		Driver File Name:\\
		Data File Name:\\
		Config File Name:\\
		Help File Name:\\
		Language Monitor Name:\\
		Default Data Type:\\
		Comma Separated list of Files
		
.fi

Any empty fields should be enter as the string "NULL". 

Samba does not need to support the concept of Print Monitors
since these only apply to local printers whose driver can make
use of a bi-directional link for communication.  This field should 
be "NULL".   On a remote NT print server, the Print Monitor for a 
driver must already be installed prior to adding the driver or 
else the RPC will fail. 
.TP 0.2i
\(bu
\fBaddprinter <printername> 
<sharename> <drivername> <port>\fR 
- Add a printer on the remote server.  This printer 
will be automatically shared.  Be aware that the printer driver 
must already be installed on the server (see \fBadddriver\fR) 
and the \fIport\fRmust be a valid port name (see
\fBenumports\fR.
.TP 0.2i
\(bu
\fBdeldriver\fR - Delete the 
specified printer driver for all architectures.  This
does not delete the actual driver files from the server,
only the entry from the server's list of drivers.
.TP 0.2i
\(bu
\fBenumdata\fR - Enumerate all 
printer setting data stored on the server. On Windows NT  clients, 
these values are stored  in the registry, while Samba servers 
store them in the printers TDB.  This command corresponds
to the MS Platform SDK GetPrinterData() function (* This
command is currently unimplemented).
.TP 0.2i
\(bu
\fBenumjobs <printer>\fR 
- List the jobs and status of a given printer. 
This command corresponds to the MS Platform SDK EnumJobs() 
function (* This command is currently unimplemented).
.TP 0.2i
\(bu
\fBenumports [level]\fR 
- Executes an EnumPorts() call using the specified 
info level. Currently only info levels 1 and 2 are supported. 
.TP 0.2i
\(bu
\fBenumdrivers [level]\fR 
- Execute an EnumPrinterDrivers() call.  This lists the various installed 
printer drivers for all architectures.  Refer to the MS Platform SDK 
documentation for more details of the various flags and calling 
options. Currently supported info levels are 1, 2, and 3.
.TP 0.2i
\(bu
\fBenumprinters [level]\fR 
- Execute an EnumPrinters() call.  This lists the various installed 
and share printers.  Refer to the MS Platform SDK documentation for 
more details of the various flags and calling options. Currently
supported info levels are 0, 1, and 2.
.TP 0.2i
\(bu
\fBgetdata <printername>\fR 
- Retrieve the data for a given printer setting.  See 
the  \fBenumdata\fR command for more information.  
This command corresponds to the GetPrinterData() MS Platform 
SDK function (* This command is currently unimplemented). 
.TP 0.2i
\(bu
\fBgetdriver <printername>\fR 
- Retrieve the printer driver information (such as driver file, 
config file, dependent files, etc...) for 
the given printer. This command corresponds to the GetPrinterDriver()
MS Platform  SDK function. Currently info level 1, 2, and 3 are supported.
.TP 0.2i
\(bu
\fBgetdriverdir <arch>\fR 
- Execute a GetPrinterDriverDirectory()
RPC to retrieve the SMB share name and subdirectory for 
storing printer driver files for a given architecture.  Possible 
values for \fIarch\fR are "Windows 4.0" 
(for Windows 95/98), "Windows NT x86", "Windows NT PowerPC", "Windows
Alpha_AXP", and "Windows NT R4000". 
.TP 0.2i
\(bu
\fBgetprinter <printername>\fR 
- Retrieve the current printer information.  This command 
corresponds to the GetPrinter() MS Platform SDK function. 
.TP 0.2i
\(bu
\fBopenprinter <printername>\fR 
- Execute an OpenPrinterEx() and ClosePrinter() RPC 
against a given printer. 
.TP 0.2i
\(bu
\fBsetdriver <printername>
<drivername>\fR
- Execute a SetPrinter() command to update the printer driver
associated with an installed printer.  The printer driver must
already be correctly installed on the print server.  

See also the \fBenumprinters\fR and 
\fBenumdrivers\fR commands for obtaining a list of
of installed printers and drivers.
.PP
\fBGENERAL OPTIONS\fR
.TP 0.2i
\(bu
\fBdebuglevel\fR - Set the current
debug level used to log information.
.TP 0.2i
\(bu
\fBhelp (?)\fR - Print a listing of all 
known commands or extended help  on a particular command. 
.TP 0.2i
\(bu
\fBquit (exit)\fR - Exit \fBrpcclient
\fR.
.SH "BUGS"
.PP
\fBrpcclient\fR is designed as a developer testing tool 
and may not be robust in certain areas (such as command line parsing).  
It has been known to  generate a core dump upon failures when invalid 
parameters where passed to the interpreter. 
.PP
From Luke Leighton's original rpcclient man page:
.PP
\fB"WARNING!\fR The MSRPC over SMB code has 
been developed from examining  Network traces. No documentation is 
available from the original creators  (Microsoft) on how MSRPC over 
SMB works, or how the individual MSRPC services  work. Microsoft's 
implementation of these services has been demonstrated  (and reported) 
to be... a bit flaky in places. 
.PP
The development of Samba's implementation is also a bit rough, 
and as more  of the services are understood, it can even result in 
versions of  \fBsmbd(8)\fR and \fBrpcclient(1)\fR 
that are incompatible for some commands or  services. Additionally, 
the developers are sending reports to Microsoft,  and problems found 
or reported to Microsoft are fixed in Service Packs,  which may 
result in incompatibilities." 
.SH "VERSION"
.PP
This man page is correct for version 3.0 of the Samba 
suite.
.SH "AUTHOR"
.PP
The original Samba software and related utilities 
were created by Andrew Tridgell. Samba is now developed
by the Samba Team as an Open Source project similar 
to the way the Linux kernel is developed.
.PP
The original rpcclient man page was written by Matthew 
Geddes, Luke Kenneth Casson Leighton, and rewritten by Gerald Carter.  
The conversion to DocBook for Samba 2.2 was done by Gerald 
Carter.